The e.bloxx modules acquire sensor and process signals with precision, speed, and stability. To ensure durability the inputs, the power supply, and the interface ports are all galvanically ioslated from each other. The industrial design reduces EMC and temperature influences to a minimum. We guarantee that our modules meet all specifications within the temperature range of -20°C to +60°C. All units can be powered with 10 to 30 VDC.
The e.bloxx modules are fully functional, intelligent, and stand alone devices. Each e.bloxx module has its own RS-485 serial port that can communicate to the automation system using Profibus-DP, Modbus-RTU, or ASCII strings.
e.bloxx A1 (Return)
 Data Sheet  | • 1, 4 or 8 universal input channels Voltage, current, resistance, Pt100, Pt1000, thermocouples,
measurement bridges
• 1 digital input per channel Status, reset
• 1 solid state relay output per channel Status, alarm, threshold, tolerance band
• ADC-conversion and signal conditioning with 19 bit up to 1000/s Linearization, digital filter, average, scaling, min/max memory,
arithmetic
• RS 485 fieldbus interface Profibus-DP, Modbus-RTU, ASCII
|
e.bloxx A3 (Return)
 Data Sheet  | • 4 or 16 galvanic isolated voltage / current input channels Differential voltage, current (with e.bloxx Terminal 4C), galvanically isolated 100VDC
• Sample rate 100/s with 4 active channels Module sample rate 400/s
• 1 digital input and 1 digital output Status, reset, alarm, threshold, tolerance band
• ADC-conversion and signal conditioning with 19 bit Linearization, digital filter, average, scaling, min/max memory,
arithmetic
• RS 485 fieldbus interface Profibus-DP, Modbus-RTU, ASCII
|
e.bloxx A4TC (Return)
 Data Sheet  | • 4 or 16 galvanic isolated Thermocouple input channels Thermocouples, voltages ±80 mV
• Dynamic linearization Optimized use of base points for type B, E, J, K, L, N, R, S, T, U, import of individual curves
• ADC-conversion and signal conditioning with 19 bit and up to 100/s Linearization, digital filter, average, scaling, min/max memory,
arithmetic
• RS 485 fieldbus interface Profibus-DP, Modbus-RTU, ASCII
|
e.bloxx A5 (Return)
 Data Sheet  | • RTD input module Pt100/Pt1000, resistance in 2, 3 or 4 wire
• 1 digital input Status, reset
• 1 digital output Status, alarm, threshold, tolerance band
• ADC-conversion and signal conditioning with 19 bit Linearization, digital filter, average, scaling, min/max memory,
arithmetic
• RS 485 fieldbus interface Profibus-DP, Modbus-RTU, ASCII
|
e.bloxx A5CR (Return)
 Data Sheet  | • 2 Input channels for Cryo sensors e.g. Type Cernox or TVO
• Sensor excitation 8 µAeff only to avoid self heading of the sensor
• Individual linearization of the sensor characteristics Sensor specific linearization by using 64 nodes and archive in a sensor data file (import function).
• 1 digital input, 1 digital output Status, alarm, limit value, tolerance band
• RS 485 fieldbus interface Profibus-DP, Modbus-RTU, ASCII
|
e.bloxx A6-2CF (Return)
 Data Sheet  | • Universal carrier frequency sensor connection Strain gauges full, half and quarter bridges, inductive bridges, LVDT
• 6 digital inputs and 4 digital outputs Functions definable, e.g. memory delete, frequency measurement, counter, alarm, threshold, tolerance band, status
• 2 analog outputs ±10 V, any variable attributable, e.g. netto and envelope curve
• ADC-conversion and signal conditioning with 19 bit and 5000/s Linearization, digital filter 4th pole, scaling, tare, min/max memory,
run/hold, envelope curve, arithmetic, alarm, threshold, tolerance band
• RS 485 fieldbus interface Profibus-DP, Modbus-RTU, ASCII
|
e.bloxx A9 (Return)
 Data Sheet  | • 4 analog outputs Voltage ±10 V and current 4..20 mA selectable
• 16 bit DAC Conversion rate up to 1000/s
• 1 digital input and 1 digital output Status, tare, reset, alarm, threshold, tolerance band
• Signal conditioning
Scaling, min/max memory, arithmetic
• RS 485 fieldbus interface Profibus-DP, Modbus-RTU, ASCII
|
e.bloxx D1 (Return)
 Data Sheet  | • 8 to 32 digital in/outputs freely configurable
• Status in-/output Process or host controlled
• Frequency in-/output
Chronos method for precise and fast frequencies measurement up to 2 MHz, frequency and PWM output
• Counter input Quadrature counter, Up/Down counter up to 400 kHz
• RS 485 fieldbus interface Profibus-DP, Modbus-RTU, ASCII
|
e.bloxx D2 (Return)
Data Sheet  | • 4 relay outputs
2 closing contacts and 2 switch able contacts
• Switching of electrical power 230 VAC / 3 A, 30 VDC / 3 A
• Many operations Expected mechanical life-span: 50,000,000 cycles
• RS 485 fieldbus interface Profibus-DP, Modbus-RTU, ASCII
|
e.bloxx D3 (Return)
 Data Sheet  | • e.bloxx D3-CAN - CAN input and output CAN node 2.0A / 2.0B ref. to ISO 11898
• e.bloxx D3-COM - RS-485 und RS-232 Master For connecting of serial devices and fieldbus slaves, standard protocol Modbus-RTU, others on request
• e.bloxx D3-SSI - RS-422 Master For connection absolute encoders (e.g. angle, displacement) with SSI (serial synchrony interface)
• 6 digital inputs and 4 digital outputs Definition of functions like status, alarm or counter
• RS 485 fieldbus interface Profibus-DP, Modbus-RTU, ASCII
|